Heat Pumps medium temperature HITACHI YUTAKI-S Combi |
|
|
|
BUILT TANK ZNX 200lit & 260lit AND FOR PRODUCTION OF HOT WATER
medium temperature (65°C) Split
air - water COOLING-HEATING
DC INVERTER |
|
|
|
|
|
|
See video installation of heat pumps in |
|
|
|
View Photo Installation of heat pumps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
New Yutaki-S Combi with Hitachi's integrated DHW PRODUCTION FOR HOT WATER, completes the basic principles of thermodynamics. No need to install additional boiler installation. |
|
|
|
|
|
It is available in 4 sizes from 3,0 kW to 17,8 kW, in cooling - heating.
The maximum water outlet temperature is 60 °C without the use of electrical resistances. |
|
|
|
|
|
|
|
|
|
Pay securely through PayPal or CARD-see details |
|
|
|
RWD-3.0FSNWE/RAS-3HVRNME-AF - medium temperature (65°C) |
|
|
|
|
|
|
|
Heat pump RWD-3.0FSNWE/RAS-3HVRNME-AF dc inverter
Capasity: heating 7,5 (3,1-11,0)kw/h - cooling 7,1 (3,0-8,0)kw/h
Compressor type: DC Scroll inverter
energy class: (Α) -- COP 4,55 -- EER 4,03
Operating limits: -20°C WB ~ +46,0°C DB
Dimensions int. / ext. (WxHxD): - / 950x800x370
Weight internal / external (Kg): - / 67
Operating current int. / ext. max MC(Α): ) - / 14,0 .... 1Ph/230V/50Hz
Sound internal / external (db): - / 42
Tank ΖΝΧ (dm3): 200 Þ 260
Design unit of software Hi-ToolKit for Home
Full pump, expansion vessel and resistance 2, 4 & 6 kw
INCLUDE THE REMOTE CONTROL PC-S80TE |
|
|
|
|
|
|
|
|
|
|
|
OFFER FOR ALL HEAT PUMPS HITACHI |
AT INCREDIBLE PRICE |
Contact on offer on the phone 0030 210 96 55 040 or mobile 0030 694 43 60 459 or email:info@karkas.gr |
|
|
target price
|
|
|
|
Transfer to all the countries of Europe |
|
|
read more ... |
|
|
|
RWD-4.0FSNWE/RAS-4HVRNME-AF - medium temperature (65°C) |
|
|
|
|
|
|
Heat pump RWD-4.0FSNWE/RAS-4HVRNME-AF dc inverter
Capasity: heating 9,8 (4,8-13,5)kw/h - cooling 10,0 (3,6-11,2)kw/h
Compressor type: DC Scroll inverter
energy class: (Α) -- COP 4,47 -- EER 3,88
Operating limits: -20°C WB ~ +46,0°C DB
Dimensions int. / ext. (WxHxD): - / 950x1.380x370
Weight internal / external (Kg): - / 107(103)
Operating current int. / ext. max (Α): ) - / - .... 1Ph-3Ph/230V-500V/50Hz
Operating current int. / ext. max (Α): ) - / .... 1Ph-3Ph/230V-500V/50Hz
Sound internal / external (db): - / 44
Tank ΖΝΧ (dm3): 200 Þ 260
Design unit of software Hi-ToolKit for Home
Full pump, expansion vessel and resistance 2, 4 & 6 kw
INCLUDE THE REMOTE CONTROL PC-S80TE |
|
|
|
|
|
|
|
OFFER FOR ALL HEAT PUMPS HITACHI |
AT INCREDIBLE PRICE |
Contact on offer on the phone 0030 210 96 55 040 or mobile 0030 694 43 60 459 or email:info@karkas.gr |
|
|
target price
|
|
|
Transfer to all the countries of Europe |
|
|
read more ... |
|
|
|
|
|
|
RWD-5.0FSNWE/RAS-5HVRNME-AF - medium temperature (65°C) |
|
|
|
|
|
|
Heat pump RWD-5.0FSNWE/RAS-5HVRNME-AF dc inverter
Capasity: heating 12,0 (6,3-16,3)kw/h - cooling 12,9 (4,7-15,0)kw/h
Compressor type: DC Scroll inverter
energy class: (Α) -- COP 4,36 -- EER 4,02
Operating limits: -20°C WB ~ +46,0°C DB
Dimensions int. / ext. (WxHxD): - / 950x1.380x370
Weight internal / external (Kg): - / 108(104)
Operating current int. / ext. max (Α): ) - / - .... 1Ph-3Ph/230V-500V/50Hz
Operating current int. / ext. max (Α): ) - / - .... 1Ph-3Ph/230V-500V/50Hz
Sound internal / external (db): - / 46
Tank ΖΝΧ (dm3): 200 Þ 260
Design unit of software Hi-ToolKit for Home
Full pump, expansion vessel and resistance 2, 4 & 6 kw
INCLUDE THE REMOTE CONTROL PC-S80TE |
|
|
|
|
|
|
|
OFFER FOR ALL HEAT PUMPS HITACHI |
AT INCREDIBLE PRICE |
Contact on offer on the phone 0030 210 96 55 040 or mobile 0030 694 43 60 459 or email:info@karkas.gr |
|
|
target price
|
|
|
Transfer to all the countries of Europe |
|
|
read more ... |
|
|
|
|
|
|
RWD-6.0FSNWE/RAS-6HVRNME-AF - medium temperature (65°C) |
|
|
|
|
|
|
Heat pump RWD-6.0FSNWE/RAS-6HVRNME-AF dc inverter
Capasity: heating 14,0 (5,9-17,8)kw/h - cooling 15,0 (4,4-17,8)kw/h
Compressor type: DC Scroll inverter
energy class: (Α) -- COP 4,11 -- EER 3,50
Operating limits: -20°C WB ~ +46,0°C DB
Dimensions int. / ext. (WxHxD): - / 950x1.380x370
Weight internal / external (Kg): - / 108(104)
Operating current int. / ext. max (Α): ) - / - .... 1Ph-3Ph/230V-500V/50Hz
Operating current int. / ext. max (Α): ) - / - .... 1Ph-3Ph/230V-500V/50Hz
Sound internal / external (db): - / 48
Tank ΖΝΧ (dm3): 200 Þ 260
Design unit of software Hi-ToolKit for Home
Full pump, expansion vessel and resistance 2, 4 & 6 kw
INCLUDE THE REMOTE CONTROL PC-S80TE |
|
|
|
|
|
|
|
OFFER FOR ALL HEAT PUMPS HITACHI |
AT INCREDIBLE PRICE |
Contact on offer on the phone 0030 210 96 55 040 or mobile 0030 694 43 60 459 or email:info@karkas.gr |
|
|
target price
|
|
|
Transfer to all the countries of Europe |
|
|
read more ... |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Return to YUTAKI |
|
|
|
|
|
|
|
|
|
|
|
Have questions?
Want information about a specific product?
Clickhere |
|
|
|
|
|
|
SEND GOODS IN EUROPE |
At incredible price all heat pumps |
Discount for purchase of more than 3 air conditioners |
Contact on offer on phone 0030210 96 55 040 or mobile 0030694 43 60 459 or email: info@karkas.gr |
|
|
|
|
|
|