SAMSUNG EHS TDM Split |
|
|
|
Heat Pumps Samsung EHS TDM low temperature (55°C)
air - water Split
COOLING - HEATING INVERTER |
|
|
|
|
|
|
See video installation of heat pumps in |
|
|
|
View PHoto Installation of heat pumps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The ideal solution for controlling the temperature in your home all year round.
|
|
|
|
|
|
The system supports EHS TDM technology heating (and cooling) air-to-air and air-water. Therefore, it is the solution fromlyti conditioning for all year round. |
|
|
|
Diagram installation EHS Split (air - water) |
|
|
|
|
technical catalog Samsung EHS (pdf 14,7 MB) |
|
|
|
|
|
|
Pay securely through PayPal or CARD-see details |
|
|
|
SINGLE PHASE UNITS |
|
Heat pump Samsung EHS TDM Split RD060PHXEA - NH080PHXEA unit Hydro |
|
|
|
|
|
|
|
RD060PHXEA - NH080PHXEA low temperature (55°C) inverter
Capasity cooling: 7,0 kw/h - Capasity heating: 6,0 kw/h
Compressor type: Rotary inverter
energy class: (Α) -- COP 4,60 -- EER 3,60
Operating limits: -20°C ~ +46°C
Dimensions external (WxHxD): 880 x 798 x 310
Dimensions internal (WxHxD): 510 x 850 x 315
Operating current (Α) (MCA / MFA) 13,5 / 16,88 .... 1PH/230V/50Hz
connection indoor units: to 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
target price
|
|
|
|
|
|
contact |
|
|
|
Heat pump Samsung EHS TDM Split RD070PHXEA - NH080PHXEA unit Hydro |
|
|
|
|
|
|
RD070PHXEA - NH080PHXEA low temperature (55°C) inverter
Capasity cooling: 7,5 kw/h - Capasity heating: 7,0 kw/h
Compressor type: Rotary inverter
energy class: (Α) -- COP 4,40 -- EER 3,40
Operating limits: -20°C ~ +46°C
Dimensions external (WxHxD): 880 x 798 x 310
Dimensions internal (WxHxD): 510 x 850 x 315
Operating current (Α) (MCA / MFA) 16,0 / 20,0 .... 1PH/230V/50Hz
connection indoor units: to 3 |
|
|
|
|
|
|
|
|
|
target price
|
|
|
|
|
contact |
|
|
|
|
Heat pump Samsung EHS TDM Split RD080PHXEA - NH080PHXEA unit Hydro |
|
|
|
|
|
|
RD080PHXEA - NH080PHXEA low temperature (55°C) inverter
Capasity cooling: 8,0 kw/h - Capasity heating: 8,0 kw/h
Compressor type: Rotary inverter
energy class: (Α) -- COP 4,15 -- EER 3,15
Operating limits: -20°C ~ +46°C
Dimensions external (WxHxD): 880 x 798 x 310
Dimensions internal (WxHxD): 510 x 850 x 315
Operating current (Α) (MCA / MFA) 18,0 / 22,5 .... 1PH/230V/50Hz
connection indoor units: to 3 |
|
|
|
|
|
|
|
|
|
target price
|
|
|
|
|
contact |
|
|
|
|
|
|
Heat pump Samsung EHS TDM Split RD110PHXEA - NH160PHXEA unit Hydro |
|
|
|
|
|
|
RD110PHXEA - NH160PHXEA low temperature (55°C) inverter
Capasity cooling: 11,3 kw/h - Capasity heating: 11,0 kw/h
Compressor type: Rotary inverter
energy class: (Α) -- COP 4,55 -- EER 3,90
Operating limits: -20°C ~ +46°C
Dimensions external (WxHxD): 932 x 1.128 x 375
Dimensions internal (WxHxD): 510 x 850 x 315
Operating current (Α) (MCA / MFA) 25,0 / 31,25 .... 1PH/230V/50Hz
connection indoor units: to 4 |
|
|
|
|
|
|
|
|
|
target price
|
|
|
|
|
contact |
|
|
Heat pump Samsung EHS TDM Split RD140PHXEA - NH160PHXEA unit Hydro |
|
|
|
|
|
|
RD140PHXEA - NH160PHXEA low temperature (55°C) inverter
Capasity cooling: 14,2 kw/h - Capasity heating: 14,0 kw/h
Compressor type: Rotary inverter
energy class: (Α) -- COP 4,36 -- EER 3,60
Operating limits: -20°C ~ +46°C
Dimensions external (WxHxD): 932 x 1.128 x 375
Dimensions internal (WxHxD): 510 x 850 x 315
Operating current (Α) (MCA / MFA) 28,0 / 35,0 .... 1PH/230V/50Hz
connection indoor units: to 4 |
|
|
|
|
|
|
|
|
|
target price
|
|
|
|
|
contact |
|
|
|
|
|
|
Heat pump Samsung EHS TDM Split RD160PHXEA - NH160PHXEA unit Hydro |
|
|
|
|
|
|
RD160PHXEA - NH160PHXEA low temperature (55°C) inverter
Capasity cooling: 15,5 kw/h - Capasity heating: 16,0 kw/h
Compressor type: Rotary inverter
energy class: (Α) -- COP 4,10 -- EER 3,30
Operating limits: -20°C ~ +46°C
Dimensions external (WxHxD): 932 x 1.128 x 375
Dimensions internal (WxHxD): 510 x 850 x 315
Operating current (Α) (MCA / MFA) 30,0 / 37,5 .... 1PH/230V/50Hz
connection indoor units: to 4 |
|
|
|
|
|
|
|
|
|
target price
|
|
|
|
|
contact |
|
|
|
|
|
|
|
|
|
|
|
|
|
Hydro internal units wall Samsung EHS TDM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
contact |
|
|
|
|
|
|
|
|
|
|
|
internal units wall Samsung EHS TDM |
|
|
|
|
|
|
Vivace wall
- NH022VHXEA, NH028VHXEA, NH036VHXEA, NH056VHXEA, NH071VHXEA
- Capasity cooling (kw/h): 2,2 - 2,8 - 3,6 - 5,6 - 6,8
- Capasity heating (kw/h): 2,5 - 3,2 - 4,0 - 6,3 - 7,0
Neo Forte wall
- NH022NHXEA, NH028NHXEA, NH036NHXEA, NH056NHXEA, NH071NHXEA
- Capasity cooling (kw/h): 2,2 - 2,8 - 3,6 - 5,6 - 6,8
- Capasity heating (kw/h): 2,5 - 3,2 - 4,0 - 6,3 - 7,0
Slim Duct καναλÜτο
- NH022LHXEA, NH028LHXEA, NH036LHXEA, NH045LHXEA, NH056LHXEA
- Capasity cooling (kw/h): 2,2 - 2,8 - 3,6 - 4,5 - 5,6
- Capasity heating (kw/h): 2,5 - 3,2 - 4,0 - 5,0 - 6,3
|
|
|
|
|
|
Vivace |
|
Neo Forte |
|
Slim Duct |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
contact |
|
|
|
Tank DHW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
contact |
|
|
|
|
|
|
|
technical catalog Samsung EHS (pdf 14,7 MB) |
|
|
Contact us for more information |
|
|
|
|
|
|
Return to SAMSUNG EHS |
|
|
|
|
|
|
|
|
|
|
|
Have questions?
Want information about a specific product?
Clickhere |
|
|
|
|
|
|
SEND GOODS IN EUROPE |
At incredible price all heat pumps |
Discount for purchase of more than 3 air conditioners |
Contact on offer on phone 0030210 96 55 040 or mobile 0030694 43 60 459 or email: info@karkas.gr |
OFFER |
AT INCREDIBLE PRICE |
Contact on offer on phone 0030 210 96 55 040 or mobile 0030 694 43 60 459 or email: info@karkas.gr |
Transfer to Europe |
|
|
|
|
|
|