daikin 14000 btu inverter FTXS42K/RXS42K/L
   

wall air conditioners DAIKIN FTXS42K/RXS42K/L - inverter

Capasity: cooling 14334(5800-17065)btu/h - heating 18430(5800-20478)btu/h

energy class Α. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
daikin 18000 btu inverter FTXS50K/RXS50K/L
   

wall air conditioners DAIKIN FTXS50K/RXS50K/L - inverter

Capasity: cooling 17065(5800-18088)btu/h - heating 19795(5800-22184)btu/h

energy class Α. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
daikin 20000 btu inverter FTXS60G/RXS60F/L
   

wall air conditioners DAIKIN FTXS60G/RXS60F/L - inverter

Capasity: cooling 20478(5800-22867)btu/h - heating 23891(5800-27304)btu/h

energy class Α. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
daikin 24000 btu inverter FTXS71G/RXS71F8
   

wall air conditioners DAIKIN FTXS71G/RXS71F8 - inverter

Capasity: cooling 24230(7850-29010)btu/h - heating 27986(7850-34812btu/h

energy class Α. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
 
FTXZ25N/RXZ25N
   
 

daikin 9000 btu inverter Ururu Sarara FTXZ25N/RXZ25N - wall air conditioners

Capasity: cooling 8530(2047-13306)btu/h - heating 12283(2047-25590)btu/h

energy class Α+++. Operating limits: -20°C  ~ +43°C

       
         
        read more ...
         
         
FTXZ35N/RXZ35N
   

daikin 14000 btu inverter Ururu Sarara FTXZ35N/RXZ35N - wall air conditioners

Capasity: cooling 11942(2047-18083)btu/h - heating 17060(2047-30708)btu/h

energy class Α+++. Operating limits: -20°C  ~ +43°C

       
         
        read more ...
 
 
FTXZ50N/RXZ50N
   

daikin 18000 btu inverter Ururu Sarara FTXZ50N/RXZ50N - wall air conditioners

Capasity: cooling 17060(2047-19789)btu/h - heating 21495(2047-32072)btu/h

energy class Α+++. Operating limits: -20°C  ~ +43°C

       
         
        read more ...
 
 
 
FTXG20L-S/W - RXG20L
   
 

daikin 7000 btu inverter Emura FTXG20L-S/W-RXG20L Air conditioning wall

Capasity: cooling 4.435-9.554 btu/h - heating 4.435-14.672 btu/h

energy class Α+++. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
         
         
FTXG25L-S/W - RXG25L
   

daikin 9000 btu inverter Emura FTXG25L-S/W-RXG25L Air conditioning wall

Capasity: cooling 4.435-10.236 btu/h - heating 4.435-15.355 btu/h

energy class Α+++. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
FTXG35L-S/W - RXG35L
   

daikin 12000 btu inverter Emura FTXG35L-S/W-RXG35L Air conditioning wall

Capasity: cooling 4.777-12.966 btu/h - heating 4.777-17.060 btu/h

energy class Α++. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
FTXG50L-S/W - RXG50L
   
 

daikin 18000 btu inverter Emura FTXG50L-S/W-RXG50L Air conditioning wall

Capasity: cooling 5.800-18.084 btu/h - heating 5.800-22.180 btu/h

energy class Α++. Operating limits: -15°C  ~ +46°C

       
         
        read more ...
 
 
 
page 5    
precedent 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 next
 
 
πληρώστε με fromλυτη ασPhάλεια μέσω PayPal ή ΚΑΡΤΑ-δείτε λεπτομέρειες
         
         
 
     
CUSTOMER INFORMATION
Full name
*
Company
Address
Zip code
City
*
Country
*
Phone
*
E-mail
*
Comments:
   
   
 
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
 
 
 
   
     
Return to top
 
Return to MENU
 

 

Have questions?

Want information about a specific product?

Click here

 
 

Phone/Fax: 0030 210 96 55 040

Mobile: 0030 6944 36 04 59

 

 

 

ALPHA CLIMA

 

OFFER
Discount for purchase of more than 3 air conditioners
Contact on offer on phone 0030210 96 55 040 or mobile 0030694 43 60 459 or email: info@karkas.gr
Transfer to all the countries of Europe

 

 

SEND GOODS IN EUROPE. For accurate calculation of transport should write the delivery address.

 

 

 

 

Tip: To select the external multi you need, first calculate the total btu/h you need the space, turning the first in m³ and then multiply by 170 if you have losses or 200 if you have losses. The result is the total btu / h you need your space. Now select your interior and you're ready.  

CAUTION. If the total is greater from 45.000 btu/h then you need mimi vrv. This is about a right way of calculating what you need your space. In the same way if you count regardless conditioners split. Certainly play a role other factors, such as the set of measures, area, elevation, etc. If you have any questions, we are happy to help you. Click here and write us your questions or call Phone.

 

 

 

 

We plant and preinstallation air conditioning and ventilation systems in buildings and constructions from licensed professionals.

 

 

 

 

What to Know and What to Include a correct installation Air Conditioning

 

 

 

 

 

 

ALPHA CLIMA